STAGE 2 & STAGE 3 | QUICK STARTMRS Installation Instruction Quick Start Guide
MAGICIAN RACE SOLUTIONS
Stage 2 & Stage 3 - Quick Start installation sequence.
- Identify your four primary vehicle integration connections: Battery Main power, constant 12V positive; Earth, battery negative; Key ON signal, switched 12V positive, present with ignition on and during cranking; and Key START signal, 12V positive only while the key is held in START.
- Disconnect the battery before beginning any wiring work.
- Mount the MRS fuse/relay box securely under the dash in a dry, accessible location.
- Install the firewall bulkhead hardware that suits your system, then route the harness through the firewall.
- Route the engine harness along its intended path and secure it clear of heat, sharp edges and moving components.
- Connect all labelled engine-side connectors and confirm each connector is fully seated and locked.
- Route and secure the cooling-fan and fuel-pump wiring. Run the fuel-pump wires rearward inside the vehicle under carpet/trim, protected from chafe or pinching, and use the supplied MRS bulkhead boot at the rear pass-through.
- Identify the vehicle circuits required for integration using the correct vehicle wiring information. Do not rely on wire colour alone.
- Connect the four primary vehicle-integration wires: Main Power - 12V+; Main Earth - Negative (-); Ignition ON - 12V+ switched; Starter Signal - 12V+ when cranking.
- Connect the required monitoring and auxiliary circuits: Tachometer / RPM Signal, Factory Oil Pressure Warning Light, Alternator Charge Warning Light, Reverse Lights, Factory Water Temperature and Gauge / Cluster connections.
- Before reconnecting the battery, complete continuity checks and verify all electrical connections are correct and secure. Ensure all required fuses are correctly installed.
- Reconnect the battery. With ignition ON, complete the pre-start electrical checks and verify the expected power and earth supplies.
- With ignition-coil power disconnected, secure and insulate the live coil-power terminal so it cannot contact earth or any conductive part. Crank the engine in short intervals and confirm oil pressure. Switch ignition OFF, then reconnect coil power.
- Start the engine and immediately confirm oil pressure. Verify warning lights, gauges and cluster functions operate correctly.
- Confirm alternator charging and correct charge-warning-light operation.
- Operate the cooling-fan manual override and verify both fans run.
- Allow the engine to reach operating temperature and confirm automatic cooling-fan operation.
- Complete a final inspection of harness support, connectors, firewall sealing, power/earth connections, fuel-pump wiring and all installed fasteners.